P9CK Industrial Diesel Generator

Features

  • Maximum 10.0 kVA, 400 V, 1500 RPM
  • 55 litre tank for 27 hrs @ 75% Load
  • Industrial brushless alternator with AVR
  • Steel baseframe, retention basin & fuel tank with sensor
  • World wide after sales service and technical support
  • Test report, manuals and electrical drawings supplied
  • Modular design

Performance

Prime Power (PRP) 9.0 kVA / 7.2 kW
Standby Power (LTP) 10.0 kVA / 8.0 kW
Power Factor 0.8 φ
Frequency 50 Hz
Voltage 400 V

Price On Request

Frequently Asked Questions

Does the price include electrical installation?

No, the price doesn't include installation. Installations are all different and require varying length of cable, time and distances to be travelled. In addition to this installations need to be done by a qualified electrician to issue a valid Certificate of Compliance (COC) for your insurance. We will gladly recommend a qualified local installer, please ask your Sales Consultant for more information.

Do we offer installation?

No, but we do have recommended installers throughout Southern Africa who will be able to assist you with your installation and sizing your generator.

Does the price include delivery?

All prices exclude delivery. Due to the nature of the goods and their size they have to be delivered by a specialised truck and rigging crew. Hence delivery is charged extra based on the distance and complexity of the delivery.

Do I need anything else to connect the generator?

Yes, you'll need either an Automatic Transfer Switch (ATS) or Manual change over switch in order to link the generator into your property's electrical distribution board. This is required by law to ensure that the generator and mains supply are adequately isolated from one another.

What size ATS do I need?

The recommended size ATS is based on the size of the generator, not the mains incoming supply. The ATS should be capable of taking the whole load from either mains or the generator as both will pass through the ATS switch. Therefore, whilst the recommended switch size will be correct for most installations, it may not be correct for your installation. You should ensure that an electrician performs a load test and checks this information.

PLEASE NOTE: ALL ratings are approximate and at SEA LEVEL. Engines need to be de-rated for altitude. A rough guide to de-rate performance is 1% for every 100m above sea level. I.e: A 20kVA at sea level is an 18kVA at 1000m above sea level (10% less) etc.

The generator will not be able to take the full load instantaneously. The load should be added to the generator gradually. 50% initially and then stepped up over time once engine is up to temperature.